Victron Energy inverter / charger MultiPlus 1600VA is short-circuit-proof and protected from overheating, either due to overload or high ambient temperature. Ring-core transformer topology has proven its reliability over many years.
The Multi Control Panel can be set to supply from a generator or shore power. MultiPlus then takes into account other AC loads and uses everything extra for charging, preventing the generator or shore power overload.
Search Mode
With Search Mode ‘on’, the inverter idle consumption is reduced by approx. 70%. In Search Mode and in inverter mode, the inverter automatically turns off when no load is connected or only a very small load is connected. Every 2 seconds, the inverter turns on and if a load is connected, the inverter stays on – if no load is connected, the inverter turns off again.
Programmable relay
By default, the relay is used as an alarm relay. The relay drops in case of alarm or warning (inverter close to overtemperature, ripple on input close to max, battery voltage close to low).
Technical data:
Output voltage: 230VAC
Dimensions: 470 x 265 x 120 mm (LxWxH) / 10.2 kg
Select voltage:
– Inverter / Charger MultiPlus 12/1600 / 70-16
Input voltage: 230VAC
Input voltage: 12V (9.5: 17V DC)
Output power AC: 1600VA
Output current DC for battery charging: 70A
Power Switch: 16A
– Inverter / Charger MultiPlus 24/1600 / 40-16 /
Input voltage: 230VAC
Input voltage: 24V (19: 33V DC)
Output power AC: 1600VA
Output current DC for battery charging: 40A
Power Switch: 16A
– Inverter / Charger MultiPlus 48/1600 / 20-16
Input voltage: 230VAC
Input voltage: 48V (38: 66V DC)
Output power AC: 1600VA
Output current DC for battery charging: 20A
Power Switch: 16A