Description
The LE300 Smart Battery System takes over most of the charging cycles while the lead-acid battery functions as cheap backup storage.
The lead-acid battery is charged with a higher priority, with the lithium battery taking up the excess energy. When discharging, the lithium battery is primarily discharged. This means that the life of the lead-acid battery is significantly extended. The LE300 detects the voltage of the lead-acid battery and automatically begins to support it with a maximum current of 12.5 A. Larger loads are supplied by the lead-acid battery and the lithium battery in parallel, which means that both batteries are discharged with less current.
Technical data :
Rated voltage 12,8 VDC, 112 Ah, max. 50A
integrated BMS
max voltage at charging 15V
Dimensions:229 x 268 x 175 mm (LxWxH)